The NEW HORIBA LAQUA PD2000 Series Benchtop Meter: pH/ORP/Ion/DO/BOD/Temp (°C/°F)

The HORIBA LAQUA PD2000 series is a versatile benchtop meter designed for precise measurement of pH, ORP, ion concentration, dissolved oxygen (DO), biological oxygen demand (BOD), and temperature in both °C and °F. It comes fully equipped with high-quality sensors and accessories for comprehensive water analysis.

What’s Included:

  • 9521-10D DO Electrode: Features a built-in temperature sensor, replaceable DO tip, detachable adapter, and stirrer.
  • 9615S-10D pH Electrode: A refillable, glass-body pH electrode with a built-in temperature sensor.
  • 502-S pH Buffers Kit: For accurate pH calibration.

Specifications:

  • pH Measurement
    • Range: -2.000 to 20.000
    • Resolution: 0.1 / 0.01 / 0.001
    • Accuracy: ±0.003 pH
  • ORP (Oxidation-Reduction Potential)
    • Range: ±2000.0 mV
    • Resolution: 0.1 mV
    • Accuracy: ±0.2 mV
    • Calibration: Up to ±200 mV
  • Ion Concentration
    • Range: 0.000 µg/L to 9999 g/L
    • Units: µg/L, mg/L, g/L, ppm, ppt, mmol/L, mol/L
    • Resolution: 4 significant digits
    • Accuracy: ±0.3% full scale or ±0.2 mV, whichever is higher
    • Calibration: Up to 5 points
  • Dissolved Oxygen (DO) Measurement
    • Range: 0.0 to 60.00 mg/L, 0.0 to 600.0%
    • Resolution: 0.01 mg/L, 0.1%
    • Accuracy: ±0.1 mg/L, ±1.0%
    • Salinity Compensation: 0.0 to 40.0 ppt
    • Barometric Pressure Compensation: 10.0 to 200.0 kPa
    • BOD Measurement: 5-day BOD with seed correction option
    • DO Probe Type: Galvanic with an integrated temperature sensor
    • Calibration: Up to 2 points
  • Temperature Measurement
    • Range: -30.0 to 130.0 °C / -22.0 to 266.0 °F
    • Resolution: 0.1 °C / °F
    • Accuracy: ±0.5 °C / ±0.9 °F
    • Calibration Option: ±10.0 °C / ±18.0 °F range in 0.1 °C increments
  • Additional Features:
    • Memory Capacity: 2000 readings
    • Auto Data Logging: Yes
    • Real-time Clock with Date & Time Stamp
    • Measurement Modes: Auto Stable, Auto Hold, Real Time
    • Offset & Slope Display: Yes (Segment & Average Slopes)
    • Calibration Alarm: Programmable up to 90 days
    • Auto Shut-Off: Programmable up to 30 minutes
    • Electrode Status Display with On-Screen Diagnostics
    • Password Protection for secure settings
    • Software Upgradeable
  • Communication & Connectivity:
    • Interfaces: Phono jack (USB / RS232C)
    • Meter Inputs: 2 x BNC, 2 x phono (ATC), DC sockets
    • Display: 5” Custom LCD with 320 segments and backlight
    • Power: AC adaptor (100 – 240V, 50 – 60Hz)

The HORIBA LAQUA PD2000 series provides precision, reliability, and ease of use, making it an ideal choice for any lab needing accurate water quality measurements