PC2000-S LAQUA pH/ORP/ION/Cond/Sal/TDS Meter Kit

Includes 9615S-10D pH/Temp ToupH Glass Refillable Electrode, 9382-10D Conductivity/Temp Electrode, pH Calibration Solutions , 84uS/cm, 1413uS/cm , 12.88mS/cm, 111.8mS/cm Conductivity Calibration Solutions, A/C power Adapter, Electrode Holder.
Note ORP Electrode NOT included. ORP 9300-10D to be Ordered Separately.
 Usually Stocked 

From: $1,995.00 ex GST

SKU: 11398

Description

Features:

Note: ORP & ION electrodes sold separately

  • pH Range: -2.000 to 20.000
  • pH Resolutions: 0.1, 0.01, & 0.001
  • pH Buffer Groups: USA, NIST, NIST2, DIN, and Custom
  • pH Calibration Points: Up to 6
  • pH Calibration Data Options: Offset, segment, and average slopes after calibration
  • pH Calibration Alarm: Adjustable up to 90 days
  • mV Range: -2000.0 to +2000.0 with ORP calibration option
  • Ion Range: 0.000 μg/L to 9999 g/L with 3 selectable units
  • Ion Calibration Points: Up to 5 user-defined
  • Ion Calibration Data Options: Segment and average slopes after calibration
  • Conductivity Range: Up to 2.000 S/cm
  • Adjustable Reference Temperature: 15 to 30 °C
  • Adjustable Temperature Coefficient: 0.00 to 10.00 % per °C
  • Cell Constant: Accepts 0.0700 to 13.000
  • Conductivity Calibration: Auto and manual calibrations, up to 5 points
  • Auto Ranging: S/cm and S/m conductivity units
  • TDS Range: 0.01 mg/L to 100 g/L
  • Pre-programmed TDS Curves: Linear (0.40 to 1.00 TDS factor), EN27888, 442, & NaCl
  • Resistivity Range: 0.000 Ω•cm to 20.0 MΩ•cm
  • Salinity Ranges: 0.0 to 100.0 ppt and 0.00 to 10.00 %
  • Pre-programmed Salinity Curves: NaCl and seawater
  • Temperature Range: -30.0 to 130.0°C / -22.0 to 266.0°F with calibration option
  • Measurement Modes: Auto stable, auto hold, and real-time
  • Indicators: Electrode status, temperature, and reading stability visible at a glance
  • Data Storage: Large memory accepting up to 2000 data sets with date/time stamp
  • Data Log: Auto function with adjustable time interval
  • Real-Time Clock: Facilitating time-dependent functions
  • Auto Shut-Off: Adjustable time up to 30 mins.
  • Security: Password-protected set-up mode
  • Upgrade Capability: Software upgradeable
  • Communication: PC communication via USB cable with complimentary data acquisition software
  • Printer Communication: Via RS232 cable
  • Display: 5” Digital, custom LCD display with backlight
  • Design: Sleek with an easy-to-use interface and audible key sound feedback
  • Compact: Small meter footprint with adjustable, integrated electrode stand
  • Warranty: 3 Years
Model LAQUA-PC2000 pH/ORP/Ion/Conductivity/
Resistivity/TDS/Salinity/Temp (°C/°F)
pH Range -2.000 to 20.000 pH
Resolution 0.1 / 0.01 / 0.001 pH
Accuracy ± 0.003 pH
pH Buffer Groups USA, NIST, NIST2, DIN, Custom
Calibration Points Up to 5 (USA, NIST, NIST2, Custom) / Up to 6 (DIN)
ORP Range ± 2000.0 mV
Resolution 0.1 mV
Accuracy ± 0.2 mV
Calibration Option Yes (Up to ± 200 mV)
Ion Range 0.000 µg/L to 9999 g/L
Units µg/L ↔ mg/L ↔ g/L, ppm ↔ ppt, mmol/L ↔ mol/L
Resolution 4 Significant digits
Accuracy ± 0.3% full scale or ± 0.2 mV, whichever is higher
Calibration Points Up to 5
Conductivity Range 0.000 to 1.999 µS/cm (k = 0.1)
2.00 to 19.99 µS/cm (k = 0.1, 1)
20.0 to 199.9 µS/cm (k = 0.1, 1, 10)
200 to 1999 µS/cm (k = 0.1, 1, 10)
2.00 to 19.99 mS/cm (k = 0.1, 1, 10)
20.0 to 199.9 mS/cm (k = 1, 10)
0.200 to 2.000 S/cm (k = 10)
Units Auto ranging S/cm, S/m (µS ↔ mS ↔ S)
Resolution 0.05% full scale
Accuracy ± 0.6% full scale; ± 1.5% full scale > 18.0 mS/cm
Reference Temperature 15.0 to 30.0 °C (adjustable)
Temperature Coefficient 0.00 to 10.00 % per °C (adjustable)
Cell Constants 0.070 to 13.00 (adjustable)
Calibration Points Up to 4 (Auto) / Up to 5 (Manual)
Resistivity Range 0.001 MΩ・cm to 20.0 MΩ・cm
Resolution 0.5% full scale
Accuracy ± 0.6% full scale; ± 1.5% full scale > 1.80 MΩ●cm
Total Dissolved Solids (TDS) Range 0.01 to 9.99 mg/L (ppm)
10.0 to 99.9 mg/L (ppm)
100 to 999 mg/L (ppm)
1.00 to 9.99 g/L (ppt)
10.0 to 100 g/L (ppt)
Resolution 0.01, 0.1, 1 mg/L ↔ g/L (ppm ↔ ppt)
Accuracy ± 0.1% full scale
TDS Curves EN27888, 442, NaCl, Linear (0.40 to 1.00)
Salinity Range 0.0 to 100.0 ppt / 0.00 to 10.00 %
Resolution 0.1 ppt / 0.01%
Accuracy ± 0.2% full scale
Salinity Curves NaCl / Seawater
Calibration Option Yes (Manual; 1 point)
Temperature Range -30.0 to 130.0 °C / -22.0 to 266.0 °F
Resolution 0.1 °C / °F
Accuracy ± 0.5 °C / ± 0.9 °F
Calibration Option Yes (± 10.0 °C / ± 18.0 °F range in 0.1 °C increments)
Memory 2000
Auto Data Log Yes
Real-time Clock Yes
Date & Time Stamp Yes
Measurement Modes Auto Stable / Auto Hold / Real Time
Offset & Slope Display Yes (Segment & Average Slopes)
Calibration Alarm Yes (Programmable: up to 90 days)
Auto Shut-Off Yes (Programmable: up to 30 mins.)
Electrode Status On screen display
Diagnostics Yes
Password Setting Yes
Software Upgrade Yes
PC / Printer Communication Phono jack (USB / RS232C)
Meter Inputs 2 x BNC, 2 x phono (ATC), DC sockets
Display 5″ Custom LCD with backlight and 320 segments
Power Requirement AC adaptor 100 – 240V, 50 – 60Hz
Dimensions & Weight 155(L) x 150(W) x 67(H) mm, 770g

CLICK HERE FOR pH CALIBRATION

CLICK HERE FOR VIEWING AND PRINTING pH CALIBRATION AND DATA

CLICK HERE FOR CONDUCTIVITY CALIBRATION

CLICK HERE FOR VIEWING AND PRINTING CONDUCTIVITY CALIBRATION DATA

CLICK HERE FOR ORP CALIBRATION

CLICK HERE FOR SALINITY CALIBRATION

CLICK HERE FOR VIEWING AND PRINTING SALINITY CALIBRATION DATA

CLICK HERE FOR ION CALIBRATION